Zoll X Series Defibrillator
Weighing under 12 pounds, the Zoll X Series Defibrillator is full-featured and designed to be effective for all patients, including neonates. Transporting a critically ill patient through the hospital requires a lightweight device with extensive monitoring capabilities. And that’s exactly what you get with the Zoll Defibrillator X Series, plus defibrillation and real-time CPR feedback in one compact device.
Description
Zoll X Series Defibrillator Features
Weighing under 12 pounds, the Zoll X Series Defibrillator is full-featured and designed to be effective for all patients, including neonates.
- Capnography
- Pulse oximetry
- Three invasive pressures
- Two temperature channels
- Non-invasive blood pressure
Zoll X Series Defibrillator Specifications
Dimensions and Weight
- Height with Handle: 10.4 in (26.4 cm)
- Height without the Handle: 8.75 in (22.2 cm)
- Width: 8.9 in (22.6 cm)
- Depth: 7.9 in (20.1 cm)
- Weight without the battery and Paper: 10.6 lbs
- Weight with the battery and paper: 11.7 lbs
Operating
- Temperature: 0to 50°CM
- Humidity: 15 to 95% RH (non-condensing)
- Vibration
- EN ISO 9919 (per IEC 60068-2-64)
- RTCA/DO-160G (multiple helicopter frequencies)
- EN 1789 for ambulance
- Shock: IEC 60068-2-27, 100g, 6ms half sine
- Drop:
- EN 1789, 30” functional drop
- IEC 60601-1, Tested at 2 meters
- Altitude: -170 M to 4572 M (-557 feet to 15,000 feet)
Temperature and Storage
- Temperature: -30 to 70°C
- Humidity: 15 to 95% RH (non-condensing)
- Atmospheric pressure: 572 mbar to 1034 mbar
- Shock/vibration: MIL-STD 810G, Method 514.6, 4.4.2, Procedure II
- Safety Classification: Class 1 and internal power per IEC/EN 60601-1
AC Auxiliary Operating Power
- Input
- 100-240V 50-60 Hz, 2A
- 100-115V 400 Hz, 2A
- Output: 14.5V 4.15A 80W (peak)
Battery
- Type: Rechargeable Lithium-Ion, 11.1Vdc, 6.6 Ah, 73Wh
- Capacity:
- At least 6 hours of continuous monitoring of ECG, SpO2, CO2, three Invasive Pressure channels, and 2 channels of Temperature, with NIBP measurements every 15 minutes and 10 200 J shocks (display set to 30%).
- At least 100 discharges at maximum shock energy (200 joules).
- At least 3.5 hours pacing, with ECG, SPO2, CO2, three Invasive Pressures, temperature, NIBP every 15 minutes, and pacing at 180 ppm, and 140 mA.
- At least 300 discharges at maximum shock energy (200 joules) with no parameters and 70% brightness.
- At least 10 discharges at maximum shock setting (200 joules) after a Low Battery indication.
- Battery Indicators: 5 Battery capacity LED indicators, Fault indicator, Recalibration indicator
- Recharge Rate: 100% in 4 hours, when initiated at Low Battery indication.
Monitor / Display
- Size: 6.5 in (16.56 cm) diagonal
- Input: 3-lead, 5-lead, or 12-lead patient cable, paddles, or multifunction electrodes
- Type: Color LCD, 640 x 480 pixels, 800 MCD
- Sweep Speed (user selectable): 25 mm/sec or 50 mm/se
- Lead Selections: Paddles (Pads), I, II, III, AVR, AVL, AVF, V1-6
- Frequency Response (user selectable)
- 0.67 – 20 Hz Limited mode
- 0.67 – 40 Hz Monitor mode
- 0.25 – 40 Hz Filtered diagnostic mode
- 0.05 – 150 Hz Diagnostic mode
Defibrillator
- Waveform: Rectilinear Biphasic
- Energy Selections: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, 30, 50, 70, 85, 100, 120, 150, 200 joules
- Energy Display: Display indicates selected and delivered energy
- Charge Time: Less than 7 seconds with a new, fully charged battery
- Charge Controls: Front panel and on apex paddle
- Pads/Paddles: Hands-free pads and external adult and pediatric paddles. Adult paddles slide off to expose pediatric paddles.
- Synchronized Mode: Synchronizes defibrillator pulse to patient’s R wave. “SYNC” message displayed on monitor and markers shown on both monitor and recorded ECG. Meets Clause 104 of AAMI DF80.
Pacer
- Type: External transcutaneous pacing
- Pacer Rate: 30 to 180 BPM ± 1.5%
- Output Current: 0 to 140 mA ± 5% or 5 mA (whichever is greater)
- Modes: Demand and Fixed