Zoll Propaq MD Defibrillator

  • Zoll Propaq MD Defibrillator
  • Zoll Propaq MD Defibrillator
  • Zoll Propaq MD Defibrillator

The Zoll Propaq MD Defibrillator is lightweight, and can be used as a monitor. The Propaq MD offers multiple display modes along with adjustable screen brightness for easy reading in direct sunlight. The display screen can show up to four waveforms at one time, as well as show the full 12-lead ECG on the display screen as well. The Zoll defibrillator runs off of a battery system and can be charged through an AC power charger, making it easy to use in a variety of settings. The Zoll Defibrillator device is Airworthy, meaning it can be operated in the air on a helicopter or other transport vehicles. The previous model of the Zoll Defibrillator is the R Series. The latest Zoll Defibrillator is the X Series.

Description

Zoll Propaq MD Defibrillator Features

The Zoll Propaq MD Defibrillator is lightweight, and can be used as a monitor. The Propaq MD offers multiple display modes along with adjustable screen brightness for easy reading in direct sunlight. The display screen can show up to four waveforms at one time, as well as show the full 12-lead ECG on the display screen as well. The Zoll defibrillator runs off of a battery system and can be charged through an AC power charger, making it easy to use in a variety of settings. The Zoll Defibrillator device is Airworthy, meaning it can be operated in the air on a helicopter or other transport vehicles. The previous model of the Zoll Defibrillator is the R Series. The latest Zoll Defibrillator is the X Series.

  • Compact, light-weight design
  • Was designed to withstand a rugged environment
  • Engineered to meet the Military standards for Airworthy devices
  • Can easily transfer the data from the defibrillator to a comprehensive monitoring system
  • Can display up to four waveforms simultaneously as well as 12-lead ECG

Zoll Propaq MD Defibrillator Specifications

Dimensions

  • Weight: 10.6 lbs. without paper and battery 11.7 lbs. with paper and battery
  • Dimensions: 8.9” x 10.4” x 7.9”
  • With soft handle: 8.9” x 8.75” x 7.9”

Display

  • Type: Bright, Color, LCD TFT
  • Brightness: User adjustable
  • Resolution: 640 x 480 pixels
  • Waveform Traces: Up to 4 waveforms
  • Display Modes: Standard, High Contrast, NVG (night vision goggle) Friendly
  • Waveform Display Width: 11.5 cm

Power

  • Rechargeable, user replaceable, lithium-ion battery
  • Operating Time: 6 hours (display brightness at 30%, ECG, Sp02, EtCO2, IPx3, Temp x2, and NIBP every 15 min, and 10 200-joule shocks)
  • Battery:
    • Size: 182 mm x 95 mm x 31 mm
    • Battery Weight: 1.36 lbs
    • Battery Indicators: 5 battery capacity LED indicators, fault indicator, recalibration indicator
    • Recharge Rate: 4 hours to 100%
    • AC Power Adapter: 100-240 VAC 50, 60, 400 Hz(@110V)

Environment

  • Operating Temperature: 0° – 50° C
  • Operating Relative Humidity: 15% – 95%, NC
  • Operating Altitude: Up to 15,000 ft
  • Transport/Storage Temperature: -30° – 70° C
  • Shock: IEC 60068-2-27, 100g, 6ms half sine

Temperature

  • Two YSI 400/700 compatible channels
  • Range: 0° – 50° C
  • Units: °C or °F
  • Display: T1, T2, and Delta temp
  • Accuracy: ± 0.1° C

Defibrillator

  • Wavform: Rectilinear BiphasicT
  • Energy Selections: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, 30, 50, 70, 85, 100, 120, 150, 200 joules
  • Energy Display: Monitor display indicates both selected and delivered energy.
  • Charge Time: < 7 seconds to 200 J, typical
  • Charge Controls: Control on the apex paddle and on the device’s front panel.
  • Paddles: External anterior/anterior adult and pediatric. Adult paddles slide off to expose pediatric paddles.
  • Synchronized Mode: Synchronizes defibrillator pulse to the patient’s R-wave. The “SYNC” message is displayed on the monitor. The marker on display and on the recorder paper identifies the R-wave discharge point.
  • Built-In Defibrillator Tester: Tests defibrillator energy output and continuity of universal cable and paddles.
  • Modes: AED function with manual override, manual defibrillation.

External Pacer

  • Type: External transcutaneous pacing
  • Pulse Types: Rectilinear, constant current
  • Pulse Width: 40 ms ± 2 ms
  • Pacer Rate: 30 – 180 BPM ± 1.5%
  • Output Current: 0 – 140 mA ± 5% or 5 mA
  • Modes: Demand and Fixed

Invasive Pressure

  • Three channels
  • Pressure Range: -30 – 300 mmHg
  • Pulse Rate Measurement Range: 25 – 250 BPM Formats: S/D, S/D (M), (M) user selectable
  • User-Selectable Labels: P1, P2, P3, ABP, AO, ART, CVP, BAP, FAP, LAP, PAP, RAP, UAP, UVP, ICP
  • Transducer Requirements: 5 μV/V/mmHg
  • Zero Adjustment: ± 200 mmHg
  • Numeric Pressure Accuracy: ± 2 mmHg or 2% of reading, plus transducer error
  • Transducer Connector: Standard 6 pin AAMI

ECG

  • Cable Detection: Automatic 3-, 5-, 12-lead
  • Input: 3-lead cable, 5-lead cable, 12-lead cable, paddles, therapy cable
  • Cable Compatibility: Propaq Encore, Propaq CS Leads: I, II, III, AVR, AVL, AVF, V1 – V6
  • Bandwidth: (User Selectable)
    • 0.67 – 20 Hz Limited mode
    • < 0.67 – 40 Hz Monitor mode
    • 0.25 – 40 Hz Filtered Diagnostic mode
  • Heart Rate Range: 30 – 300 BPM
  • Heart Rate Accuracy: ± 3 BPM or 3%
  • Pacer detection and display
  • Electrosurgery interference suppression
  • ESU and defibrillation protected
  • ECG Sizes: 0.125, 0.25, 0.5, 1, 2, 4 cm/mv, and auto-ranging
  • Sweep Speed: 25 mm/sec, 50 mm/sec Common Mode Rejection: Complies with AAMI

Patient Mode

    User Selectable: Adult, Pediatric, Neonate. Sets defaults for alarms, defibrillation energy, and NIBP settings.

Trends (on Screen)

  • Tabular numeric format
  • All parameters trended/viewable
  • Trend Intervals: 1, 5, 10, 15, 30, 60 minutes Duration: 24 hours at 1-minute intervals
  • Snapshots: Minimum of 32 display data captures (12 seconds of pre- and post-button press)
  • Quick Access Trend Display via Display Button

Printer

  • Waveforms Printed: 1, 2, or 3
  • Print Speeds: 25 mm/sec or 50 mm/sec
  • Print Modes: Manual or automatic (user configurable)
  • On/Off Control: Front panel or paddle
  • Paper Delay: 6 seconds
  • Frequency Response: Same as the monitor’s settings
  • Paper Width: 80 mm