Zoll AED Plus Defibrillator

  • Defibrillators Zoll AED Plus Defibrillator

The first AED to provide a complete look at resuscitation. The ZOLL AED Plus guides rescuers through the entire rescue process. Uses a brilliant new graphics/voice user interface to help the rescuer every step of the way.

Description

Zoll AED Plus Defibrillator Features

The first AED to provide a complete look at resuscitation. The ZOLL AED Plus Defibrillator guides rescuers through the entire rescue process. Uses a brilliant new graphics/voice user interface to help the rescuer every step of the way.

  • Real CPR Help provides real-time CPR feedback on the rate and depth of chest compressions
  • Audio prompts and visual icons complement the American Heart Association’s Chain of Survival
  • Easy-to-place, one-piece CPR-D-padz® electrodes with a 5-year shelf life
  • Fully automatic feature available — unit will deliver a shock on its own when a shockable heart rhythm is detected
  • Rugged design with an IP (ingress protection) rating of IP55 for dust and water
  • Can withstand conditions like extreme temperature, altitude, vibration, and shock
  • Off-the-shelf lithium batteries (Duracell 123a) with a 5-year battery life
  • Intelligent pediatric capability: Pedi-padz® pediatric electrodes can be purchased separately for children up to 8 years old or weighing less than 55 pounds
  • Automatic self-testing helps ensure a state of readiness
  • Soft carry case for easy travel
Measuring Chest Compression with Real CPR Help
The force required to depress the chest during CPR varies with the patient’s size and build. The standard
measure of chest compression quality, however, is not force but depth. The Real CPR Help® technology in
ZOLL’s CPR-D-padz® includes a hand-placement locator, an accelerometer, electronics, and a processing
algorithm that work together to measure vertical displacement in space as each compression occurs.
One Size Fits All
ZOLL’s one-piece electrode design accounts for anatomical variation. Based on extensive human data,
CPR-D-padz meets the anthropometric chest characteristics of 99% of the population. If needed, the lower
(apex) electrode can be separated and adjusted to accommodate the remaining 1% of the population.
Simplified Placement
Affixing two separate electrode pads to the patient’s bare chest can be confusing to a lay rescuer.
ZOLL’s CPR-D-padz simplifies this step by guiding the placement of the red crosshairs at the center of the
imaginary line connecting the patient’s nipples. Once in place, the hand-locator and the two electrode
pads fall naturally into the optimal position for both defibrillation and CPR.
Five-Year Shelf Life
All AED electrodes transmit defibrillating electricity into the patient via metal in close contact with
a salt-infused gel that is positioned between the metal and the skin. Over time, however, the salt
in the gel will corrode the metal and eventually compromise electrode functionality. ZOLL’s novel
electrode design includes a sacrificial element that prevents significant corrosion for five years, which
is unmatched in the market today.

Zoll X Series Defibrillator Specifications

Dimensions and Weight

  • Height: 5.25″ (13.3 cm)
  • Width: 9.50″ (24.1 cm)
  • Depth: 11.50″ (29.2 cm)
  • Weight: 6.7 lbs (3.1 kg)

Waveform

  • Rectilinear Biphasic

Charge Time

  • Less than 10 seconds with new batteries

Defibrillator Charge Hold Time

  • 30 seconds

Energy Selection

  • Automaticpreprogrammed selection
  • (120J, 150J, 200J)

Patient Safety

  • All patient connections are electrically isolated

Electrodes

  • ZOLL CPR-D-padz, pedi-padz® II or stat-padz® II

Self-test

  • Configurable automatic self-test from 1 to 7 days.
  • Default = every 7 days. Monthly full-energy test (200J).

CPR

  • Metronome Rate: Variable 60 to 100 CPM

Depth

  • 3/4″ to 3.5″; 1.9 to 8.9 cm

Automatic Self-Test Checks

  • Battery capacity, electrode connection, electrocardiogram and charge/discharge circuits, microprocessor hardware and software, CPR circuitry and CPR-D sensor, and audio circuitry

Defibrillation Advisory

  • Evaluates electrode connection and patient ECG to determine if defibrillation is required

Shockable Rhythms

  • Ventricular fibrillation with average amplitude >100 microvolts and wide complex ventricular tachycardia with rates greater than 150 BPM for adults, 200 BPM for pediatrics. For ECG Analysis Algorithm sensitivity and specificity, refer to AED Plus Administrator’s Guide

Patient Impedance Measurement Range

  • 0 to 300 ohms

Defibrillator

  • Protected ECG circuitry

Display Format

  • Size: 2.6″ x 1.3″; 6.6 cm x 3.3 cm
  • (OPTIONAL) LCD with moving bar

(OPTIONAL) ECG Viewing Window

  • 2.6 seconds

(OPTIONAL) ECG Display Sweep Speed

  • 25 mm/sec; 1″/sec

Battery Capacity

  • Typical new (20°C) = 5 years (225 shocks) or 13 hours continuous monitoring. End of life designated by Red X (typical remaining shocks = 9).

Data Recording and Storage

  • 50 minutes of ECG and CPR data. If the audio recording option is installed and enabled, 20 minutes of audio recording, ECG, and CPR data. If audio recording is disabled, 7 hours of ECG and CPR data.

PC Minimum Requirements For Configuration and Patient Data Recovery

  • Windows® 98, Windows® 2000, Windows® NT, Windows® XP, Windows® 7, Windows® 8, and Windows® 10 IBM-compatible PII with 16550 UART (or higher) computer.
  • 64MB RAM.
  • VGA monitor or better.
  • CD-ROM drive. IrDA port.
  • 2MB disk space.

Power

  • User-Replaceable Batteries. 10 Type 123A Photo Flash lithium manganese dioxide batteries

Device Classification

  • Class II and internally powered per EN60601-1

Design Standards

  • Meets applicable requirements of UL 2601, AAMI
  • DF-39, IEC 601-2-4, EN60601-1, IEC60601-1-2

Environmental

  • Operating Temperature
    • 32° to 122°F; 0° to 50°C
  • Storage Temperature
    • -22° to 140°F; -30° to 60°C

Humidity

  • 10 to 95% relative humidity, non-condensing

Vibration

  • MIL Std. 810F, Min. Helicopter Test

Shock

  • IEC 68-2-27; 100G

Altitude

  • -300 to 15,000 ft.; -91m to 4573 m

Particle and Water Ingress

  • IP-55

CPR-D-padz

  • Shelf Life:
    • 5 years
  • Conductive Gel:
    • Polymer Hydrogel
  • Conductive Element:
    • Tin
  • Packaging:
    • Multilayer foil laminate pouch
  • Impedance Class:
    • Low
  • Cable Length:
    • 48 in (1.2 m)
  • Sternum:
    • Length: 6.1 in (15.5 cm)
    • Width: 5.0 in (12.7 cm)
    • Length, conductive gel: 3.5 in (8.9 cm)
    • Width, conductive gel: 3.5 in (8.9 cm)
    • Area, conductive gel: 12.3 sq in (79.0 sq cm)
  • Apex:
    • Length: 6.1 in (15.5 cm)
    • Width: 5.6 in (14.1 cm)
    • Length, conductive gel: 3.5 in (8.9 cm)
    • Width, conductive gel: 3.5 in (8.9 cm)
    • Area, conductive gel: 12.3 sq in (79.0 sq cm)
  • Complete Assembly:
    • Folded Length: 7.6 in (19.4 cm)
    • Folded Width: 7.0 in (17.8 cm)
    • Folded Height: 1.5 in (3.8 cm)
  • Design Standards
    • Meets applicable requirements of ANSI/AAMI/ISO DF-39-1993

Additional information

Brand

Zoll