Philips HeartStart MRx Defibrillator
Built to be rugged, reliable, and easy-to-use, the HeartStart MRx with the Philips DXL 12-Lead ECG algorithm, provides industry-leading patient monitoring capabilities, superb diagnostic measurements, proven resuscitation therapies, and CPR guidance.
The Philips HeartStart MRx Monitor/Defibrillator, seamlessly provides industry-leading patient monitoring, superb diagnostic measurements, and evidenced-based, proven resuscitation therapies in an intuitive and easy-to-use design.
Description
Philips HeartStart MRx Defibrillator Features
The Philips HeartStart MRx Defibrillator unites Philips’ industry-leading monitoring technologies with superior diagnostic measurements and the patented SMART Biphasic resuscitation waveform in a single, thoughtfully designed, lightweight device.
- Seamless wireless data transmission of 12-lead ECGs with optional Wireless Link
- Ease-of-use is the hallmark of all Philips defibrillators and the MRx is no exception. In the moment of need, the MRx’s intuitive and easy-to-use design can help your team save a life.
- Clinical networking capability on the IntelliVue Clinical Network for monitoring and review at the central station. MRx is the only monitor/defibrillator that has the ability to connect to a clinical monitoring network.
- The MRx uses a scalable platform for use as a crash cart or as a high-end critical care transport monitor, the MRx can be easily upgraded in-house so that you can receive the benefits of Philips advancements now and into the future.
- Standardized alarms, cables, and interchangeable accessories among Philips defibrillators and IntelliVue patient monitors mean enhanced ease of use and “plug and play” patient hand-off, as well as simplified inventory management and reduced costs using the MRx.
- The large color screen displays 4 waveforms and numerics, or all 12 leads and numerics
- Flexible Event Summary allows configuration of the data you want
- Time-Insensitive Predictive Instrument (ACI-TIPI) helps predict the probability of acute ischemia
- Thrombolytic Predictive Instrument (TPI) helps predict the patient outcome with and without thrombolytic therapy
- SMART Biphasic therapy for high first shock efficacy for long downtime SCA patients
- Quick Shock for fast time to shock
Philips HeartStart MRx Defibrillator Specifications
Philips HeartStart MRx Defibrillator Dimensions and Weight
MRx Dimensions (Without External Paddles)
- Width: 12.4 in (31.3 cm)
- Depth: 8.3 in (21 cm)
- Height: 11.7 in (29.5 cm)
MRx Dimensions (With External Paddles)
- Width: 13.4 in (34 cm)
- Depth: 8.3 in (21 cm)
- Height: 13.6 in (34.5 cm)
Weight
- 13.2 lbs. (6kg): Base unit with 1 MRx battery, pads, and pads cable.
- +4.1 lbs. (1.86 kg): With added MRx carrying case.
- +2.5 lbs. (1.1 kg): With added MRx paddle tray and external standard paddles.
Battery
- Type: 6.3 Ah, 14.8 V, rechargeable lithium-ion Ah/V
- Dimensions: 6.5″ (H) x 3.8″ (W) x 1.6″ (D) (165 mm x 95 mm x 42 mm) “/ mm
- Capacity: At least 5 hours of continuous 12-lead ECG/SpO2 and CO2 monitoring.With NBP every 15 minutes on one new fully charged battery hours.
- Weight: 1.6 lb. (0.73 kg) lb/ kg
- Charge Time: Approximately 3 hours from fully depleted to 100%. 90 minutes from fully depleted to 80% hours/%.
- Capacity(b): At least 3.5 hours of continuous 12-lead ECG/SpO2 and CO2 monitoring. With NBP every 15 minutes and pacing at 180 ppm at 160 mA on one new fully charged battery hours.
End-tidal CO2
- Range: 0 to 99 mmHg mmHg
- Resolution: 1 mmHg (0.1 kPa) mmHg/kPa
- Sample Size: 50 ml per minute ml
- Alarm Range(h):
- Low Limit: 10 to 95 mmHg (Adult/Pediatric) mmHg
- Alarm Range(i):
- High Limit: 20 to 100 mmHg (Adult/Pediatric) mmHg
Power Supply
- Type: 6.3 Ah, 14.8 V, rechargeable lithium-ion Ah/V
Environmental & Physical Requirements:
- Solids/Water Resistance: IP24
- Operating Temperature: 0º – 45º C (32º – 113º F) ° C/° F
- Storage Temperature: -20 – 70º C (-4º – 158º F) ° C/° F
- Operating Humidity: 0% to 95% relative %
- Operating Altitude: 0 to 15000 ft (0 to 4500 m) ft/ m
- Storage Altitude: 0 to 15000 ft (0 to 4500 m) ft/ m
- Mechanical Shock:
- Bump: IEC 68-2-29
- Freefall: IEC 68-2-32
- Operating Vibration: MIL-STD 810E 514.4 Category 6 Helicopter
- General Storage Vibration: UH60 Non-Operating: IEC 68-2-6 Swept Sine Vibration and IEC 68-2-64 Random Vibration
- Safety: Meets EN 60601-1, UL 2601-1/CSA C22.2 No. 601-1
Display
- Dimensions: 8.4’’ diagonal (128 mm x 171 mm) “/ mm
- Type: TFT color LCD
- Resolution: 1 mmHg (0.1 kPa) mmHg/kPa
- Resolution: 480 x 640 pixels (VGA)
- Wave Viewing Time: 5 seconds (ECG) seconds
Defibrillation
- Waveform: Truncated Exponential Biphasic. Waveform parameters adjusted as a function of patient impedance.
- Output Energy:
- Manual (selected): 1-10/15/20/30/50/70/100/120/150/170/200
- Joules into a 50 Ohm load AED Mode (single energy output): 150 Joules into a 50-ohm load. Joules/Ohm
- Charge Time: Less than 5 seconds to 200 Joules with a new/ fully charged lithium-ion battery at 25º C
- Shock Delivery: Via multifunction defib electrode pads or paddles
- Shock-to-Shock Cycle Time: Typically less than 20 seconds
- Minimum Patient Impedance Range: 15 Ohm (internal defibrillation); 25 Ohm (external defibrillation) Ohm
- Maximum Patient Impedance Range: 180 Ohm
- AED Mode: Shock advisory sensitivity and specificity meet AAMI DF-39 guidelines
Noninvasive Blood Pressure
- Pressure Range(a):
- Systolic: 40 to 260 mmHg
- Pressure Range(b):
- Diastolic: 20 to 200 mmHg
- Initial Pressure:
- Adult: 160 mmHg and Pediatric: 120 mmHg
- Maximum Pressure: 280 mmHg
- Alarm Range(d):
- Systolic high limit: 30 – 270 (Adult) and 35 – 180 (Pediatric)
- Alarm Range(e):
- Systolic low limit: 30 – 265 (Adult) and 30 – 175 (Pediatric)
- Alarm Range(f):
- Diastolic high limit: 18 – 240 (Adult) and 18 – 150 (Pediatric)
- Alarm Range(g):
- Diastolic low limit: 10 – 240 (Adult) and 10 – 145 (Pediatric)
Strip Chart Recorder
- Recorder(a):
- Standard: 50 mm (paper width) thermal array printer mm
- Recorder(b):
- Optional: 75 mm (paper width) thermal array printer mm
- Continuous ECG Strip: Prints primary ECG lead with event annotations and measurements in real-time or with a 10-second delay
- Auto Printing: The recorder can be configured to print marked events/charge/ shock and alarms
- Reports: Event Summary, 12-Lead/Operational Check/Configuration/Status Log and Device Information
- Paper Size: 1.97” (50 mm) W by 100 ft. (30 m) L and 2.95” (75 mm) W by 100 ft. (30 m) L “/ft/mm/m
Data Storage
- Internal: 12 hours of continuous ECG waveforms and events. Plus 50 12-lead ECG reports
- Data Card: 12 hours of continuous ECG waveforms and events. Plus 50 12-lead ECG reports on a Compact Flash memory card
ECG and Arrhythmia Monitoring
- Input: Up to 4 ECG waves displayed and up to 3 ECG waves print simultaneously.
- Leads: Lead I, II, or III obtained through 3-lead ECG cable and separate monitoring electrodes. With 5-lead cable, obtain leads I/II/III/aVR/aVL/ aVF or V.Pads ECG obtained through 2 multifunction defibrillation electrode pads.
- Lead Fault: ‘Lead Off ’ message and dashed line displayed if an electrode or lead wire becomes disconnected.
- Pads Fault: Dashed line displayed if a pad becomes disconnected.
- Heart Rate Display: Digital readout on display 15 to 300 bpm with accuracy ±10% bpm/%
- Heart Rate/Arrhythmia Alarms: HR/Asystole/VFIB/VTACH/VTACH/extreme tachycardia/extreme bradycardia/PVC rate.
- ECG Size: 2.5/5/10/20/40 mm/mV autogain mm/mV
SpO2 Pulse Oximetry
- Range: 0 to 100 %
- Resolution: 0.01 %
- Alarm Range(a):
- Low Limit: 50 to 99% (Adult/Pediatric) %
- Alarm Range(b):
- High Limit: 51 to 100% (Adult/Pediatric) %
- Alarm Delay: 10 seconds
12-Lead ECG
- Input:
- 12-Lead cable: leads I/II/III/aVR/aVL/ aVF and V/C1-V/C6
- Display View: All 12-lead ECG waves display simultaneously
- Strip Recorder: All 12-leads print on the strip chart printer in 3×4 format
- Transmission: CompactFlash data card; Bluetooth® dial-up Internet connection, Bluetooth® FTP
CPR Feedback and Measurement
- Compression Depth:
- Target: -1.50 to -2.00″ (-38 to -51 mm) “/ mm
- Compression Rate:
- Target: 90 to 120 cpm cpm
- Ventilation Volume:
- Graphic Indicator: Empty/one-third full/two-thirds full/full
- Ventilation Rate(a):
- The target for breaths delivered before 60 seconds since the last compression: 6 to 16 vpm seconds/vpm
- Ventilation Rate(b):
- The target for breaths delivered beyond 60 seconds since the last compression: 9 to 16 vpm seconds/vpm
Noninvasive Pacing
- Current Pulse Amplitude: 10 mA to 160 mA (5 mA resolution); accuracy 10 mA to 50 mA ± 5 mA, 50 mA – 160 m A ± 10% mA
- Pulse Width: 40 ms with ± 10% accuracy ms/%
- Rate: 30 ppm to 180 ppm (10 ppm increments); accuracy ± 1.5% ppm
- Modes: Demand or Fixed Rate
- Refractory Period: 340 msec (30 to 80 ppm); 240 msec (90 to 180 ppm) msec/ppm
Additional information
Brand | Philips |
---|