Pelton-Crane Delta Q8 Autoclave

  • Pelton-Crane Delta Q8 Autoclave

The Pelton-Crane Delta Q8 Autoclave features closed-door drying, which prevents the interruption of the full sterilization process by allowing instruments to dry completely in an enclosed, clean environment. This steam pressure autoclave is used in a range of settings, including active surgery centers, medical practice, dental offices, schools, veterinary facilities, industrial labs, doctor’s clinics, or tattoo establishments.

Product Overview Button

Description

Pelton-Crane Delta Q8 Autoclave Features

The Pelton-Crane Delta Q8 Autoclave features closed-door drying, which prevents the interruption of the full sterilization process by allowing instruments to dry completely in an enclosed, clean environment. This steam pressure autoclave is used in a range of settings, including active surgery centers, medical practice, dental offices, schools, veterinary facilities, industrial labs, doctor’s clinics, or tattoo establishments.

  • Type: Steam.
  • Approved for hand piece sterilization.
  • Closed door filtered air drying ensures wet packs and pouches dry without compromising sterility of instruments by airborne contaminants.
  • Variable timed drying cycle saves time by giving operator the flexibility to set the drying time.
  • Automatic chamber preheat maximizes productivity by shortening cycle times.
  • Electronic temperature and time control systematically monitor sterilization conditions in chamber to ensure cycle completion.
  • One custom and four automatic programmed sterilization settings allow you to select the appropriate cycle according to type of load.
  • Digital function display allows easy and accurate monitoring of sterilization cycle.
  • Vent valve will open and the P-2 alarm will display if the chamber pressure exceeds 240 kPa.
  • Safety valve opens as backup protection should the chamber pressure exceed 262 kPa.
  • Chamber temperature is monitored by a surface sensor with overheat protection should the temperature of the heating elements reach 180 °C.
  • In case of electrical power interruption during the sterilization cycle, pressure in the chamber is automatically vented to the atmosphere and display is blank.

Pelton-Crane Delta Q8 Autoclave Specifications

Dimensions and Weight

  • Height: 12.5″ (31 cm) (with Stand)
  • Width: 17.25″ (44 cm) (with Stand)
  • Depth: 19.75″ (50 cm) (with Stand)
  • Weight: 61 lbs (28 kg) (Without Water)

Chamber Size:

  • Height: 9.875″ (25.1 cm)
  • Width: 9.875″ (25.1 cm)
  • Depth: 17.5″ (44.5 cm)

Chamber Capacity:

  • 12.11 L (739 cubic inches)

Trays:

  • Small: 14″ x 5″ x 0.75″
  • Large: 14″ x 7″ x 0.75″

Start-Up Time (To 134° C):

  • 10 – 13 minutes warm.

Total Cycle Time:

  • 16 minutes warm (unwrapped).

Drying Cycle:

  • 30 minutes pre-programmed, variable 0 – 99 minutes.

Electrical:

  • 110 – 120 VAC, 50/60 Hz (ETL/cETL)
  • Requires dedicated 20 amp circuit.