Datascope Passport 2 Monitor

  • Datascope Passport 2 Monitor Multiparameter and ECG Monitors

The Datascope Passport 2 Monitor features an incredibly intelligent display interface that allows the user to evaluate patient status at a glance. Data is presented clearly, concisely and logically. Waveforms are aligned to digital data for immediate interpretation. Graph and list displays are easily configured to personal preference. The 4 Auto-Set Alarms program is quickly configured and extremely easy to use. Best of all, personalized custom settings retained on the PCMCIA cards assure super-fast set-up.

Description

Datascope Passport 2 Monitor Features

The Datascope Passport 2 Monitor features an incredibly intelligent display interface that allows the user to evaluate patient status at a glance.

  • Incredibly intelligent display interface
  • Data is presented clearly, concisely and logically
  • Waveforms are aligned to digital data for immediate interpretation
  • Graph and list displays are easily configured to personal preference
  • 4 Auto-Set Alarms program are quickly configured and extremely easy to use
  • Personalized custom settings retained on the PCMCIA cards assure super fast set-up

Datascope Passport 2 Monitor Specifications

Display:

  • Screen Size:
    • 10.4 inch (26.4 cm) Color TFT
  • Resolution:
    • VGA 640-480
  • Waveforms:
    • 3 to 6

Datascope Passport 2 Monitor Dimensions (H x W x D):

  • 9.5” H x 12” W x 7.5” D

Weight:

  • 15 lbs. Including (2) Batteries
  • 11.4 lbs. Excluding Batteries

ECG (3-Lead & 5-Lead):

  • Leads:
    • I, II, III, aVR, aVL, aVF, V
  • Cable Detection:
    • Autodetecting Datascope 3 or 5 wire
  • Display Sensitivity:
    • 0.25, 0.5, 1.0, 2.0, 3.0, 4.0, cm/mV +/- 10%

Frequency Response To Screen

  • Extended Mode:
    • 0.05-100 Hz, -3db max @ 1mVpp input
  • Monitor Mode:
    • 0.5 – 40 Hz, -3db max @ 1mVpp input (ESU filter disabled)
  • ST Mode:
    • 0.05 – 40 Hz, -3db max @ 1mVpp input
  • CMRR:
    • 90 db min, Maximum output of 1mVp-p (RTI) over 60 seconds at 50/60 Hz, with parallel combination 51K Ω and 0.047 uF imbalance and +/- 300 mV DC offset per AAMI EC13-1992 3.2.9.10

ECG Sync Pulse for Cardioversion:

  • Delay:
    • ≤35 ms max between QRS Peak and rising edge of Sync Pulse
  • Amplitude:
    • 2Vp minimum into a 5k ohm load
  • Width:
    • 2-7 msec
  • Analog Output:
    • (ECG)
  • Delay:
    • 25ms max
  • Sensitivity:
    • 1 V/mV of input, +/- 10%
  • Defibrillator Overload Protection:
    • Withstand 360 Joule discharge as per IEC 60601-2-27, 51.101.1
  • Recovery Time:
    • Time for recovery to within 1mV in < 8 seconds automatically. 3 seconds from 1Vpp at 60Hz

ECG (12-Lead):

  • Leads:
    • I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6
  • Connection Type:
    • Type II PCMCIA card to be installed in PCM 1 slot
  • Cable Detection:
    • Automatically enabled when 12-lead Card is inserted into PCM 1 slot

Frequency Response

  • Extended Mode:
    • 0.05-100 Hz, -3db max @ 1mVpp input
  • Monitor Mode:
    • 0.5 – 40 Hz, -3db max @ 1mVpp input (ESU filter disabled)
  • ST Mode:
    • 0.05 – 40 Hz, -3db max @ 1mVpp input
  • CMRR:
    • 90 db min, Maximum output of 1mVp-p (RTI) over 60 second period at 50/60 Hz, with a parallel combination 51K Ω and 0.047 uF imbalance and +/- 300 mV DC offset per ANSI/AAMI EC11-1991, 3.2.11
  • Analog Output (ECG):
    • Disabled when 12-lead ECG analysis is enabled
  • Defibrillator Overload Protection:
    • Withstand 360 joule discharge as per IEC 60601-2-27, 51.101.1

HEART RATE METER

  • Range:
    • 30 – 300 BPM Adult/Pediatric, 30 – 350 BPM Neonate 3-lead and 5-lead/ 30 – 300 BPM 12-lead
  • Accuracy:
    • +/- 3BPM or +/- 3% at 30 – 250BPM whichever is greater, +/- 5% at 251 – 350 BPM
  • Pacer Rejection:
    • Rejects all pulses of amplitude +/- 2.0 mV to 700 mV and duration 0.1 to 2 ms with no tail. AAMI EC-13-1992 3.1.4.1 (3-Lead and 5-Lead) Rejects all pulses of amplitude +/- 2.0 mV to 700 mV and duration 0.1 to 2 ms with 100 ms time constant tail of less than 2.0 mV, or 4 ms time constant tail of < 2.0 mV per AAMI EC-13-1992 3.1.4.2
  • Tall T-Wave Rejection:
    • Rejects all T-Waves less than 120% of 1 mV QRS and Q-T interval of 350 ms per AAMI EC-13-1992 3.1.2.1 (c)

ST ANALYSIS

  • 3-lead or 5-lead Range:
    • -9.9 mm to +9.9 mm
  • 12-lead Absolute Range:
    • -10 mm to +10 mm
  • 12-lead Delta Range:
    • -20 mm to +20 mm
  • Resolution:
    • 0.1 mm
  • Default ST Measuring Point:
    • 80 ms after J point for HR ≤ 120 bpm, 60 ms after J point for HR >120 bpm

ARRHYTHMIA ANALYSIS

3-lead or 5-lead cables:

  • Adult / Pediatric Only:
    • Asystole, Irregular Heart Rate, Couplets, Bigeminy, Trigeminy, Ventricular Tachycardia, Ventricular Fibrillation, PVC’s per minute, Runs, Ventricular, Rhythm and Bradycardia

12-lead:

  • Adult / Pediatric Only:
    • Asystole, Couplets, Runs, Bigeminy, Trigeminy, Ventricular Tachycardia, Ventricular Fibrillation, PVC’s per minute, Ventricular Rhythm, and Pause

RESPIRATION (ECG)

  • Range:
    • 4 to 199 BPM
  • Accuracy:
    • +/- 2% or 2 breaths per minute whichever is greater from 4 to 150 BPM, +/- 4% from 151 to 199 BPM
  • Lead:
    • I or II

NON – INVASIVE BP

  • Technique:
    • Oscillometric
  • Systolic Range:
    • Adult – 55-235 mmHg Pediatric – 55-160 mmHg Neonate – 45-120 mmHg
  • Diastolic Range:
    • Adult – 30-200 mmHg Pediatric – 30-150 mmHg Neonate – 20-100 mmHg
  • Systolic Accuracy:
    • Mean Error less than +/- 5 mmHg, Standard Deviation less than +/- 8 mmHg
  • Diastolic Accuracy:
    • Mean Error less than +/- 5 mmHg, Standard Deviation less than +/- 8 mmHg

Pulse Rate Range:

  • Adult/Pediatric:
    • 35 to 245 BPM
  • Neonate:
    • 70 to 245 BPM
  • Pulse Rate Accuracy:
    • +/-3 BPM or 3% whichever is greater
  • Connector Type:
    • Rectus
  • Cuff Inflation:
    • Volume of 500cc to 300 mmHg in ≤35 sec

TEMPERATURE

  • Scale:
    • Selectable C° or F°
  • Range:
    • 15° to 45° C / 59° to 113° F
  • Accuracy:
    • +/- 0.1° C (15° C to 45° C) exclusive of probe errors. +/- 0.2° F (59° F to 113° F) exclusive of probe errors.

PULSE OXIMETRY

  • Classification per ISO 9919:
    • Functional Saturation Oximeter

Masimo SET® SpO2 Accuracy Saturation with NO Motion Conditions:

  • Adult/Pediatric:
    • 70% to 100% +/- 2 digits SpO2, 0-69% unspecified
  • Neonate:
    • 70% to 100% +/- 3 digits SpO2, 0-69% unspecified
  • Ear Sensor (Adult/Pediatric):
    • 70% to 100% +/- 4 digits SpO2, 0-69% unspecified

Masimo SET® SpO2 Accuracy Saturation DURING Motion Conditions

  • Adult/Pediatric/Neonate:
    • 70% to 100% +/- 3 digits SpO2
  • Response Time:
    • 18 seconds to 95% of final step of % SpO2 value from 60-95% at 75 BPM. Averaging set at 8 seconds.

Pulse Rate Range Masimo with NO motion conditions

  • Adult/Pediatric/Neonate:
    • 30-235 ±3 BPM, Ear Sensor (Adult/Pediatric) 30-235 ± 3BPM

Pulse Rate Range Masimo DURING Motion Conditions

  • Adult/Pediatric/Neonate:
    • 30-235 ±5 BPM

Low Perfusion Performance

Masimo:

  • < 0.02% Pulse Amplitude and % Transmission < 5% / Saturation (% SpO2) ± 2 digits; Pulse ± 3 digits

Nellcor® Oxismart® SpO2 Saturation Accuracy:

  • Adult/Pediatric/Neonate:
    • 70% to 100% +/- 2 digits
  • Note: Adult sensor D-25, Neonate sensor N-25
  • Pulse Rate Range Nellcor:
    • 20-249 ±3 BPM

IBP

  • Range:
    • Sys/Dia/Mean –30 – +300 mmHg
  • Accuracy:
    • +/- 2 mmHg or 2% whichever is greater
  • Scale:
    • -10 to 10, 0-20, 0-40, 0-160, 0-225, 0-320, 60-140 mmHg
  • Zero Range:
    • +/- 120 mmHg
  • Excitation:
    • 5V DC +/- 2%
  • Frequency Response:
    • DC to 16 Hz +/- 1Hz, -3db

RECORDER

  • Speed:
    • 3.125, 6.25, 12.5, 25mm, and 50mm/sec
  • Note: 3.125 speed is for CO2/Resp only.

CO2 (Microstream®)

  • Range:
    • 0 – 99 mmHg
  • Accuracy:
    • 0 – 38 mmHg +/- 2 mmHg 39 – 99 mmHg +/- 5% + .08% for every 1mmHg above 40mmHg
  • Respiration Rate:
    • 0-150 breaths per minute
  • Respiration Accuracy:
    • +/- 1 breath per minute from 0 – 40 BPM +/- 2 BPM from 41– 70 BPM +/- 3% from 71 – 100 BPM +/- 5% from 101 – 150 BPM

CO2 Waveform

  • Recognition:
    • 5 mmHg +/- 2 mmHg bandwidth
  • Start-up Time:
    • 30 seconds typical
  • Sampling Rate:
    • 50 ml/min +/- 7.5 ml/min
  • Auto Zero:
    • < 15 seconds at 5, 10, 15 and 60 minute then every 60 minutes thereafter.

ELECTRICAL RATINGS

  • AC Voltage:
    • 100 – 240 VAC +/- 10%, 50/60 Hz +/- 3 Hz
  • Battery Type:
    • Sealed Lead Acid
  • Number of Batteries:
    • 2
  • Battery Voltage:
    • 12 Vdc @ 2.3A load
  • Battery Capacity:
    • 2.3 AH each
  • Battery Run Time:
    • 1hr and 50 min. from two fully charged batteries at 25° C with ECG, SpO2 and 1 NIBP every 15 minutes, no recording, no CO2.
  • Recharge Time:
    • 16 hrs max

ENVIRONMENTAL CONDITIONS

  • Storage Temperature:
    • -20°C – + 60°C/-4°F – +140°F
  • Storage Humidity:
    • 10 – 95% non-condensing
  • Operating Altitude:
    • -1250 to 9,889 feet ASL, 1060hPa to 700hPa, 795 mmHg to 525 mmHg
  • Operating Temperature:
    • 5°C to 40°C/41°F – 104°F
  • Operating Humidity:
    • 15% to 95%, non-condensing

Additional information

Brand

Datascope