Datascope Passport 2 Monitor
The Datascope Passport 2 Monitor features an incredibly intelligent display interface that allows the user to evaluate patient status at a glance. Data is presented clearly, concisely and logically. Waveforms are aligned to digital data for immediate interpretation. Graph and list displays are easily configured to personal preference. The 4 Auto-Set Alarms program is quickly configured and extremely easy to use. Best of all, personalized custom settings retained on the PCMCIA cards assure super-fast set-up.
Description
Datascope Passport 2 Monitor Features
The Datascope Passport 2 Monitor features an incredibly intelligent display interface that allows the user to evaluate patient status at a glance.
- Incredibly intelligent display interface
- Data is presented clearly, concisely and logically
- Waveforms are aligned to digital data for immediate interpretation
- Graph and list displays are easily configured to personal preference
- 4 Auto-Set Alarms program are quickly configured and extremely easy to use
- Personalized custom settings retained on the PCMCIA cards assure super fast set-up
Datascope Passport 2 Monitor Specifications
Display:
- Screen Size:
- 10.4 inch (26.4 cm) Color TFT
- Resolution:
- VGA 640-480
- Waveforms:
- 3 to 6
Datascope Passport 2 Monitor Dimensions (H x W x D):
- 9.5” H x 12” W x 7.5” D
Weight:
- 15 lbs. Including (2) Batteries
- 11.4 lbs. Excluding Batteries
ECG (3-Lead & 5-Lead):
- Leads:
- I, II, III, aVR, aVL, aVF, V
- Cable Detection:
- Autodetecting Datascope 3 or 5 wire
- Display Sensitivity:
- 0.25, 0.5, 1.0, 2.0, 3.0, 4.0, cm/mV +/- 10%
Frequency Response To Screen
- Extended Mode:
- 0.05-100 Hz, -3db max @ 1mVpp input
- Monitor Mode:
- 0.5 – 40 Hz, -3db max @ 1mVpp input (ESU filter disabled)
- ST Mode:
- 0.05 – 40 Hz, -3db max @ 1mVpp input
- CMRR:
- 90 db min, Maximum output of 1mVp-p (RTI) over 60 seconds at 50/60 Hz, with parallel combination 51K Ω and 0.047 uF imbalance and +/- 300 mV DC offset per AAMI EC13-1992 3.2.9.10
ECG Sync Pulse for Cardioversion:
- Delay:
- ≤35 ms max between QRS Peak and rising edge of Sync Pulse
- Amplitude:
- 2Vp minimum into a 5k ohm load
- Width:
- 2-7 msec
- Analog Output:
- (ECG)
- Delay:
- 25ms max
- Sensitivity:
- 1 V/mV of input, +/- 10%
- Defibrillator Overload Protection:
- Withstand 360 Joule discharge as per IEC 60601-2-27, 51.101.1
- Recovery Time:
- Time for recovery to within 1mV in < 8 seconds automatically. 3 seconds from 1Vpp at 60Hz
ECG (12-Lead):
- Leads:
- I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6
- Connection Type:
- Type II PCMCIA card to be installed in PCM 1 slot
- Cable Detection:
- Automatically enabled when 12-lead Card is inserted into PCM 1 slot
Frequency Response
- Extended Mode:
- 0.05-100 Hz, -3db max @ 1mVpp input
- Monitor Mode:
- 0.5 – 40 Hz, -3db max @ 1mVpp input (ESU filter disabled)
- ST Mode:
- 0.05 – 40 Hz, -3db max @ 1mVpp input
- CMRR:
- 90 db min, Maximum output of 1mVp-p (RTI) over 60 second period at 50/60 Hz, with a parallel combination 51K Ω and 0.047 uF imbalance and +/- 300 mV DC offset per ANSI/AAMI EC11-1991, 3.2.11
- Analog Output (ECG):
- Disabled when 12-lead ECG analysis is enabled
- Defibrillator Overload Protection:
- Withstand 360 joule discharge as per IEC 60601-2-27, 51.101.1
HEART RATE METER
- Range:
- 30 – 300 BPM Adult/Pediatric, 30 – 350 BPM Neonate 3-lead and 5-lead/ 30 – 300 BPM 12-lead
- Accuracy:
- +/- 3BPM or +/- 3% at 30 – 250BPM whichever is greater, +/- 5% at 251 – 350 BPM
- Pacer Rejection:
- Rejects all pulses of amplitude +/- 2.0 mV to 700 mV and duration 0.1 to 2 ms with no tail. AAMI EC-13-1992 3.1.4.1 (3-Lead and 5-Lead) Rejects all pulses of amplitude +/- 2.0 mV to 700 mV and duration 0.1 to 2 ms with 100 ms time constant tail of less than 2.0 mV, or 4 ms time constant tail of < 2.0 mV per AAMI EC-13-1992 3.1.4.2
- Tall T-Wave Rejection:
- Rejects all T-Waves less than 120% of 1 mV QRS and Q-T interval of 350 ms per AAMI EC-13-1992 3.1.2.1 (c)
ST ANALYSIS
- 3-lead or 5-lead Range:
- -9.9 mm to +9.9 mm
- 12-lead Absolute Range:
- -10 mm to +10 mm
- 12-lead Delta Range:
- -20 mm to +20 mm
- Resolution:
- 0.1 mm
- Default ST Measuring Point:
- 80 ms after J point for HR ≤ 120 bpm, 60 ms after J point for HR >120 bpm
ARRHYTHMIA ANALYSIS
3-lead or 5-lead cables:
- Adult / Pediatric Only:
- Asystole, Irregular Heart Rate, Couplets, Bigeminy, Trigeminy, Ventricular Tachycardia, Ventricular Fibrillation, PVC’s per minute, Runs, Ventricular, Rhythm and Bradycardia
12-lead:
- Adult / Pediatric Only:
- Asystole, Couplets, Runs, Bigeminy, Trigeminy, Ventricular Tachycardia, Ventricular Fibrillation, PVC’s per minute, Ventricular Rhythm, and Pause
RESPIRATION (ECG)
- Range:
- 4 to 199 BPM
- Accuracy:
- +/- 2% or 2 breaths per minute whichever is greater from 4 to 150 BPM, +/- 4% from 151 to 199 BPM
- Lead:
- I or II
NON – INVASIVE BP
- Technique:
- Oscillometric
- Systolic Range:
- Adult – 55-235 mmHg Pediatric – 55-160 mmHg Neonate – 45-120 mmHg
- Diastolic Range:
- Adult – 30-200 mmHg Pediatric – 30-150 mmHg Neonate – 20-100 mmHg
- Systolic Accuracy:
- Mean Error less than +/- 5 mmHg, Standard Deviation less than +/- 8 mmHg
- Diastolic Accuracy:
- Mean Error less than +/- 5 mmHg, Standard Deviation less than +/- 8 mmHg
Pulse Rate Range:
- Adult/Pediatric:
- 35 to 245 BPM
- Neonate:
- 70 to 245 BPM
- Pulse Rate Accuracy:
- +/-3 BPM or 3% whichever is greater
- Connector Type:
- Rectus
- Cuff Inflation:
- Volume of 500cc to 300 mmHg in ≤35 sec
TEMPERATURE
- Scale:
- Selectable C° or F°
- Range:
- 15° to 45° C / 59° to 113° F
- Accuracy:
- +/- 0.1° C (15° C to 45° C) exclusive of probe errors. +/- 0.2° F (59° F to 113° F) exclusive of probe errors.
PULSE OXIMETRY
- Classification per ISO 9919:
- Functional Saturation Oximeter
Masimo SET® SpO2 Accuracy Saturation with NO Motion Conditions:
- Adult/Pediatric:
- 70% to 100% +/- 2 digits SpO2, 0-69% unspecified
- Neonate:
- 70% to 100% +/- 3 digits SpO2, 0-69% unspecified
- Ear Sensor (Adult/Pediatric):
- 70% to 100% +/- 4 digits SpO2, 0-69% unspecified
Masimo SET® SpO2 Accuracy Saturation DURING Motion Conditions
- Adult/Pediatric/Neonate:
- 70% to 100% +/- 3 digits SpO2
- Response Time:
- 18 seconds to 95% of final step of % SpO2 value from 60-95% at 75 BPM. Averaging set at 8 seconds.
Pulse Rate Range Masimo with NO motion conditions
- Adult/Pediatric/Neonate:
- 30-235 ±3 BPM, Ear Sensor (Adult/Pediatric) 30-235 ± 3BPM
Pulse Rate Range Masimo DURING Motion Conditions
- Adult/Pediatric/Neonate:
- 30-235 ±5 BPM
Low Perfusion Performance
Masimo:
- < 0.02% Pulse Amplitude and % Transmission < 5% / Saturation (% SpO2) ± 2 digits; Pulse ± 3 digits
Nellcor® Oxismart® SpO2 Saturation Accuracy:
- Adult/Pediatric/Neonate:
- 70% to 100% +/- 2 digits
- Note: Adult sensor D-25, Neonate sensor N-25
- Pulse Rate Range Nellcor:
- 20-249 ±3 BPM
IBP
- Range:
- Sys/Dia/Mean –30 – +300 mmHg
- Accuracy:
- +/- 2 mmHg or 2% whichever is greater
- Scale:
- -10 to 10, 0-20, 0-40, 0-160, 0-225, 0-320, 60-140 mmHg
- Zero Range:
- +/- 120 mmHg
- Excitation:
- 5V DC +/- 2%
- Frequency Response:
- DC to 16 Hz +/- 1Hz, -3db
RECORDER
- Speed:
- 3.125, 6.25, 12.5, 25mm, and 50mm/sec
- Note: 3.125 speed is for CO2/Resp only.
CO2 (Microstream®)
- Range:
- 0 – 99 mmHg
- Accuracy:
- 0 – 38 mmHg +/- 2 mmHg 39 – 99 mmHg +/- 5% + .08% for every 1mmHg above 40mmHg
- Respiration Rate:
- 0-150 breaths per minute
- Respiration Accuracy:
- +/- 1 breath per minute from 0 – 40 BPM +/- 2 BPM from 41– 70 BPM +/- 3% from 71 – 100 BPM +/- 5% from 101 – 150 BPM
CO2 Waveform
- Recognition:
- 5 mmHg +/- 2 mmHg bandwidth
- Start-up Time:
- 30 seconds typical
- Sampling Rate:
- 50 ml/min +/- 7.5 ml/min
- Auto Zero:
- < 15 seconds at 5, 10, 15 and 60 minute then every 60 minutes thereafter.
ELECTRICAL RATINGS
- AC Voltage:
- 100 – 240 VAC +/- 10%, 50/60 Hz +/- 3 Hz
- Battery Type:
- Sealed Lead Acid
- Number of Batteries:
- 2
- Battery Voltage:
- 12 Vdc @ 2.3A load
- Battery Capacity:
- 2.3 AH each
- Battery Run Time:
- 1hr and 50 min. from two fully charged batteries at 25° C with ECG, SpO2 and 1 NIBP every 15 minutes, no recording, no CO2.
- Recharge Time:
- 16 hrs max
ENVIRONMENTAL CONDITIONS
- Storage Temperature:
- -20°C – + 60°C/-4°F – +140°F
- Storage Humidity:
- 10 – 95% non-condensing
- Operating Altitude:
- -1250 to 9,889 feet ASL, 1060hPa to 700hPa, 795 mmHg to 525 mmHg
- Operating Temperature:
- 5°C to 40°C/41°F – 104°F
- Operating Humidity:
- 15% to 95%, non-condensing
Additional information
Brand | Datascope |
---|