GE Corometrics 170 Series Fetal Monitors
Whether you perform antepartum fetal monitoring in an office setting or in the hospital, Corometrics* 170 Series Fetal Monitor can help. You can trust our fetal monitors to help you improve the standard of care for your expecting mothers. We designed these compact, lightweight monitors to help you effectively and efficiently care for mom and baby by accurately and noninvasively tracking the baby’s heart rate for non-stress tests. The 170 series is used with our Nautilus* watertight and lightweight Toco and 9-crystal Ultrasound transducers for comfortable and reliable monitoring.
Description
GE Corometrics 170 Series Fetal Monitors Features
The GE Corometrics 170 Series Fetal Monitors provide the ability to address every monitoring need for both the mother and fetus.
- Single Ultrasound and Uterine Activity
- External
- Alerts you to fetal heart rate concerns – The fetal heart rate alarm provides both audible and visual alerts if the heart rate is higher or lower than the range you set as normal
- Helps you place the transducer – Independent volume controls make it easier to locate the transducer for most effective monitoring
- Can monitor multiple heart rates – There is an option to monitor twins
- Displays important information prominently – The large, easy-to-read LCD display clearly presents information about fetal heart rate and uterine activity
- Offers portability – An optional mobile roll stand cart lets you transport the monitor and all of its necessary accessories
Models of the 170 Series
- Model 171 – The Model 171 Antepartum Fetal Monitor provides singleton ultrasound and external uterine activity monitoring.
- Model 172 – The Model 172 Antepartum Fetal Monitor provides dual ultrasound and external uterine activity monitoring.
- Model 173 – The Model 173 Intrapartum Monitor provides dual heart rate monitoring using FECG and ultrasound. The monitor also provides external uterine activity monitoring using a toco transducer or internal monitoring using an intrauterine pressure catheter (IUPC).
- Model 174 – The Model 174 Intrapartum Monitor provides dual heart rate monitoring using FECG/ultrasound or dual ultrasound. The monitor also provides external uterine activity monitoring using a toco transducer or internal monitoring using an IUPC.
GE Corometrics 170 Series Fetal Monitors Specifications
Dimensions and Weight
- Height: 5.75 in (14.6 cm)
- Width: 16.75 in (42.5 cm)
- Depth: 10 in (25.4 cm)
- Weight: 8 lbs (3.6kg)
Environmental Operating Conditions
- Ambient Temperature: 50°F to 104°F (10°C to 40°C)
- Relative Humidity: 10% to 75%, non-condensing
Environmental Storage Conditions
- Ambient Temperature: 14°F to 131°F (–10°C to 55°C)
- Relative Humidity: 10% to 90%, non-condensing
Power Requirements
- Nominal Line Voltage: 100-230 VAC
- Line Frequency: 50/60 Hz (operates over 47-63 Hz)
- Power Consumption: ≤30 VA
- Monitor DC Input: 12 Vdc at 2.5A
Operating Specifications
- Technique Pulsed Doppler with autocorrelation processing
- Transducer Type: 9-crystal
- Pulse Repetition: 2 kHz (all modes)
- Frequency Pulse Duration: 92 μs
- Transmitter Frequency: 1.151 MHz
- Spatial – Average Temporal: Isata <5 mW/cm2
- Average Intensity
- Focal 20 dB Beam Area 16.6 cm2, at a range = 7 cm
- Peak Instantaneous 1.8 mW/cm2
- Intensity
- Heart Rate Counting Range: 50-210 BPM
- Leakage Current Complies with IEC 60 1.1 and/or IEC 601.1.1 harmonized national standard; Complies with EN 60601-1-2:2002
FECG Mode
- Technique: Peak detecting, beat-to-beat cardio tachometer
- Heart Range Counting Range: 30-240 BPM
- Heart Rate Resolution: 1 BPM
- Artifact Elimination: service selectable, ±25 BPM artifact rejection
- Countable Input Signal Range: 15µV to 2mV peak-to-peak
- Offset Voltage Tolerance (differential): ±300 mVdc maximum
- Maximum Common-mode Voltage: 20V peak-to-peak
- Common Mode Rejection: Balanced: >120 dB at mains frequency, with patient cable, Unbalanced 5kΩRA or LA: >110 dB at mains frequency
- Input Impedance: Differential: >10MΩ; Common mode: >20MΩ
- Mains Frequency Rejection: >40 dB
- Leakage Current: complies with IEC 601.1 and/or IEC 601.1.1 harmonized national standard
- Isolation, Mains-to-patient: >5656 Vdc
Ultrasound Mode
- Technique: Pulsed Doppler with autocorrelation processing
- Transfer Transducer Type: 9-crystal
- Pulse Repetition Frequency: 2 kHz (all modes)
- Pulse Duration: 92 µs
- Transmitter Frequency: 1.151 MHz
- Spatial – Average Temporal Average Intensity: Isata<5 mW/ cm2
- Focal 20 dB Beam Area: 16.6 cm
, at a range = 7 cm - Peak Instantaneous Intensity: 1.8 mW/cm2
- Heart Rate Counting Range: 50-210 BPM
- Leakage Current: complies with IEC 601.1 and/or IEC 601.1.1 harmonized national standard
Additional information
Brand | GE |
---|