Carefusion Alaris 8120 PCA Infusion Pump Module
The Alaris® PCA module is a syringe-based PCA infusion device that provides quick access to total dose history and monitors trending data giving you additional tools to analyze and address a patient’s response to pain therapy.
Description
Carefusion Alaris 8120 PCA Infusion Pump Module Features
The Carefusion Alaris® 8120 PCA Infusion Pump Module works with the Alaris 8015 PC unit. The Alaris 8120 Module is used for the delivery of pain management medications via patient-controlled dosing in a locked clear case.
The Alaris® Medley 8120 PCA Syringe module is part of a comprehensive IV medication safety system with a common user interface shared across multiple infusion modalities. The 8120 is designed to work with the Alaris PC Unit as well as with other Alaris System modules.
The Alaris® PCA module is a syringe-based PCA infusion device that provides quick access to total dose history and monitors trending data giving you additional tools to analyze and address a patient’s response to pain therapy
Use this module to customize the Alaris® 8000 or 8015 PC Unit Infusion Pumps
- Reduced respiratory failure
- Decreased adverse drug events
- Monitoring for all at-risk patients
- The PCA infusion pauses if the patient’s respiratory parameter falls below hospital-defined EtCO2 or SpO2 limits.
- Guardrails™ MX drugs error reduction software helps reduce adverse drug events.
- The module follows industry best practice recommendations for continuous EtCO2 and SpO2 monitoring.
Hospira Lifecare PCA Syringe Pump Specifications
Dimensions and Weight
- Height: 15 in
- Width: 4.5 in
- Depth: 7.5 in
- Weight: 5.5lbs
Bolus Volume After Occlusion, Maximum
- High: .997mL
- Low: .396 mL
Bolus Delivery Rate
- 150 mL/hr
- 75-500 mL/hr (limited by syringe size)
Lockout Interval
- 1 – 180 minutes in 1-minute increments
- Min/max 1 – 180 minutes
Max. Accumulated Dose Range
- 1-hour limit
- Disabled/1, 2, or 4-hour limit
Max Rate
- 999 mL/hr
- 0.1 – 99.9 mL/h in 0.1 mL/h increments; 100 – 999 mL/h in 1 mL/h increments
Occlusion Pressure SetPoint
- High: 800 mmHg
- Low: 200 mmHg
- Medium: 500 mmhm
Reduced respiratory failure
- The PCA infusion pauses if the patient’s respiratory parameter falls below hospital-defined EtCO2 or SpO2 limits.
Decreased adverse drug events
- Guardrails™ MX drugs error reduction software helps reduce adverse drug events.
Monitoring for all at-risk patients
- The module follows industry best practice recommendations for continuous EtCO2 and SpO2 monitoring.