Bovie IDS 310 Electrosurgical Unit

  • Bovie IDS 310 Electrosurgical Unit Electrosurgical Units

The Bovie IDS 310 Electrosurgical Unit was designed in conjunction with OR clinicians to provide a safe, user-friendly generator to meet all operating room procedure performance demands. This innovative energy-based device offers 13 modes of surgical energy delivery. Special modalities include the advanced Bovie Bipolar, Auto Bipolar options, and special Laparoscopic modes. These modes were included to assist surgeons in tailoring all electrosurgery needs for their variety of surgical applications and user preferences.

Description

Bovie IDS 310 Electrosurgical Unit Features

  • Bovie Bipolar – Pulsing coagulation for quick and powerful coagulation of tissue
  • Auto Bipolar – Offers immediate and simplified tissue coagulation with minimal tissue damage
  • Specialized Laparoscopic Mode – Recalls up to 10 presets and up to 6 bipolar output preferences
  • Adjustable Power During Activation

Bovie IDS 310 Electrosurgical Unit Specifications

Dimensions and Weight

  • Width: 6.5 In (16.5 cm)
  • Height: 14.75 In (37.5 cm)
  • Depth: 18.1 In (46 cm)
  • Weight: < 9.07 kg (< 20 lbs.)

General

  • Contact Monitoring Systems: BovieNEM
  • Contact Monitoring Systems
    • Range/Trip Point: 10 ohms or less over entire operating range (10C° to 40°C)
  • Cooling System: Passive Cooling
  • Technology: Isolated RF Output
  • Pre-set Feature: Yes
  • Monopolar HP Ports: 2
  • Dual Activation Tone Alert: Yes
  • Connector Ports/Power Switch: Black

Bipolar

  • Macro Bipolar
    • Watts: 150
    • VPeak Max Voltage: 600V
    • Crest Factor (Typical): 1.5 ± 20%
    • Frequency: 490 kHz ± 4.9 kHz
  • Micro Bipolar
    • Watts: 80
    • VPeak Max Voltage: 450V
    • Crest Factor (Typical): 1.5 ± 20%
    • Frequency: 490 kHz ± 4.9 kHz
  • Standard Bipolar
    • Watts: 50
    • VPeak Max Voltage: 300V
    • Crest Factor (Typical): 1.5 ± 20%
    • Frequency: 490 kHz ± 4.9 kHz
  • Bovie Bipolar
    • Watts: 225
    • VPeak Max Voltage: 250V
    • Crest Factor (Typical): 1.5 ± 20%
    • Frequency: 490 kHz ± 4.9 kHz
  • Auto Bipolar
    • Watts: 80
    • Frequency: 490 kHz ± 4.9 kHz

Monopolar

  • Cut I
    • Watts: 300
    • VPeak Max Voltage: 1000V
    • Crest Factor (Typical): 1.7 ± 20%
    • Frequency: 490 kHz ± 4.9 kHz
  • Cut II
    • Watts: 300
    • VPeak Max Voltage: 750V
    • Crest Factor (Typical): 1.7 ± 20%
    • Frequency: 490 kHz ± 4.9 kHz
  • Blend (1)
    • Watts: 200
    • VPeak Max Voltage: 1320V
    • Crest Factor (Typical): 1.8 ± 20%
    • Frequency: 490 kHz ± 4.9 kHz
  • Blend (2)
    • Watts: 200
    • VPeak Max Voltage: 1475V
    • Crest Factor (Typical): 2.0 ± 20%
    • Frequency: 490 kHz ± 4.9 kHz
  • Blend (3)
    • Watts: 200
    • VPeak Max Voltage: 1650V
    • Crest Factor (Typical): 2.2 ± 20%
    • Frequency: 490 kHz ± 4.9 kHz
  • Blend (4)
    • Watts: 200
    • VPeak Max Voltage: 1870V
    • Crest Factor (Typical): 2.4 ± 20%
    • Frequency: 490 kHz ± 4.9 kHz
  • Pinpoint Coagulation
    • Watts: 120
    • VPeak Max Voltage: 1800V
    • Crest Factor (Typical): 3.1 ± 20%
    • Frequency: 490 kHz ± 4.9 kHz
  • Spray Coagulation
    • Watts: 120
    • VPeak Max Voltage: 4000V
    • Crest Factor (Typical): 6.0 ± 20%
    • Frequency: 350 to 450 kHz
  • Gentle Coagulation
    • Watts: 120
    • VPeak Max Voltage: 450V
    • Crest Factor (Typical): 1.6 ± 20%
    • Frequency: 490 kHz ± 4.9 kHz