Axia V1500A Touch Screen Patient Monitor

  • Axia V1500A Touch Screen Patient Monitor Multiparameter and ECG Monitors

The Axia V1500A Touch Screen Patient Monitor is designed for a fast-paced work environment with an intuitive touchscreen. The patient information along with vital sign settings can be quickly modified to meet the needs of a patient’s changing condition. Its upgradeable design fits-in and moves amongst many patient care areas. Offers ECG with arrhythmia detection, standard measurements of non-invasive blood pressure, motion tolerant SpO2, temperature, respiration rate, and capnography.

The Axia V1500A monitor offers several connective solutions to network multiple monitors and/or manage patient data on an electronic medical records platform or a based hospital information system.

Description

Axia V1500A Touch Screen Patient Monitor Features

The Axia V1500A Touch Screen Patient Monitor is designed for a fast-paced work environment with an intuitive touchscreen.

  • Optional: integrated Dräger 5-Agent Anesthesia Gas Bench with CO2 capabilities
  • High resolution 15 inch touch-screen display
  • Capnography with EtCO2 monitoring (optional)
  • Auto setting of alarm limits
  • Color-coded alarms
  • Graphical and tabular trends (72 hours)
  • Patient data entry
  • OxiCRG, drug dose calculation
  • Trace: 8 wave forms
  • Trend Time: 1 – 72 Hours
  • Networking capability (wireless and non-wireless)
  • Color of the waveforms can be changed
  • Battery backup (removable batteries)
  • Weight: 10.85 lbs.
  • Applications: Neonatal, pediatric and adult patients

Axia V1500A Touch Screen Patient Monitor SPECIFICATIONS

GENERAL

  • Display
    • 12.1 inch color touch screen
  • Trace
    • 8 waveforms
  • Indicator
    • Alarm indicator
    • Power indicator
    • ORS beep and alarm sound
  • Trend Time
    • 1 – 72 hour
    • Recorder: Built-in, thermal array, 3 channels Record width: 48mm
    • Recorder paper: 50mm
    • Record speed: 25mm/s, 50mm/s

NETWORKING

  • Industry standard 802.11 b/g wireless network

POWER

  • Source:
    • External AC power or internal battery
  • AC Power:
    • 100 ~ 240VAC, 50/60Hz, 150VA
  • Battery:
    • Built-in & rechargeable lithium ion
  • Operating Time:
    • 3+ hours

ENVIRONMENTAL SPECIFICATIONS

  • Temperature:
    • Operating: 5 ~ 40 °c
    • Storage: -20 ~ 65 °c
  • Humidity range:
    • Operating: s80 %
    • Storage: s80 %

ECG

  • Input:
    • 5-lead ECG cable and standard AAMI line for connection
  • Lead Choice:
    • I, 11, 111, aVR, aVF, aVL, V, V1-V6, TEST
  • Gain Choice:
    • x0.5, x1, x2, x4
  • Frequency Characteristic:
    • 0.05 ~ 35 HZ (+3dB)
  • ECG Waveforms:
    • 7 channels
  • Penetration Voltage:
    • 4000VAC 50/60Hz
  • Sweep Speed:
    • 12.5, 25, 50 and 100 mm/sec (left to right or right to left)
  • HR Display Range:
    • 30 ~300bpm
  • Accuracy:
    • ±1bpm or ±1%, whichever is greater
  • Alarm Limit Range Setting:
    • upper limit 100 ~ 200bpm, lower limit 30 ~ 100bpm

RESP

  • Measure Method:
    • RA-LL impedance
  • Range:
    • O ~ 120 rpm
  • Accuracy:
    • ±3 rpm
  • Alarm Limit Setting:
    • upper limit 6 ~ 120 rpm
    • lower limit 3 ~ 120 rpm
  • Sweep Speed:
    • 12.5, 25, 50 and 100 mm/sec (left to right or right to left)

SPO2

  • ASpO2:
    • Anti-motion SpO2
  • SpO2% Range:
    • 0-100%
  • SpO2 Accuracy:
    • ±2% (70 ~ 100%, non-motion)
    • ±3% (70 ~ 100%, motion)
  • Pulse Rate Range:
    • 30-250 bpm
  • Pulse Rate Accuracy:
    • ±2 bpm (non-motion)
    • ±3 bpm (motion)
  • Alarm Limit Setting:
    • upper limit 70 ~ 100%
    • lower limit 70 ~ 100%
  • SpO2 Probe:
    • Red light LED wavelength 660nm±5nm
    • Infrared light LED wavelength 940nm±10nm

NIBP

  • Measuring Technology:
    • Automatic oscillating measurement
  • Cuff Inflating:
    • <30s (0 ~ 300 mmHg, standard adult cuff)
  • Measuring Period:
    • AVE <40s
  • Mode:
    • Manual, Auto
  • Measuring Interval in AUTO Mode:
    • 2 min~ 4 hrs
  • Pulse Rate Range:
    • 30 ~ 250 (bpm)
  • Adult/Pediatric Mode:
    • SYS: 40 ~ 250 (mm Hg)
    • DIA :15 ~ 200 (mmHg)
  • Neonatal Mode:
    • SYS: 40 ~ 135 (mmHg)
    • DIA : 15 ~ 100 (mmHg)
  • Maximum Mean error:
    • ±5mmHg
  • Maximum Standard deviation:
    • 8mmHg
  • Resolution:
    • 1mmHg
  • Overpressure Protection:
    • Adult Mode: 300 (mmHg)
  • Neonatal Mode:
    • 160 (mmHg)
  • Alarm Limit Setting:
    • SYS: 50 ~ 240 mmHg
    • DIA: 15 ~ 180 mmHg

TEMPERATURE

  • Range:
    • 25 ~ 50 (°C)
  • Accuracy:
    • ± 0.2 °c (25.0 ~ 34.9°C)
    • ± 0.1 °C (35.0 ~ 39.9°C)
    • ± 0.2 °C (40.0 ~ 44.9°C)
    • ± 0.3 °C (45.0 ~ 50.0°C)
  • Display Resolution:
    • 0.1°c
  • Alarm Limit Setting:
    • Upper limit o ~ 50°C
    • Lower limit o ~ 50°C
  • Channel:
    • 2 channels

IBP

  • Measurement Range:
    • -50 ~ 300mmHg
  • Channel:
    • 2 channels
  • Pressure Transducer:
    • Sensitivity, 5µVN/mmHg
  • Impedance Range:
    • 300~30000
  • Transducer Sites:
    • ART, PA,CVP, RAP, LAP, ICP
  • Unit:
    • mmHg/kPa selectable
  • Resolution:
    • 1mmHg
  • Accurancy:
    • ±1 mmHg or ±2%, whichever is greater
  • Alarm Range:
    • -10 ~ 300mmHg

ETC02

  • CO2Measurement Range:
    • 0~99mmHg
  • Accuracy:
    • ±2mmHg (0 ~ 38mmHg)
    • 39-99mmHg ±5% of reading +0.08% for every 1 mmHg (above 38mmHg)
  • Sampling Rate:
    • 50 ml/min
  • Initialization Time:
    • 30 seconds (typical), reaches ±5% Steady-state accuracy within 3 minutes.
  • Respiration Rate:
    • 0 ~ 150 breaths
  • Mode:
    • Adult, Neonate

C.O. (CARDIAC OUTPUT)

  • Measurement Method:
    • Thermodilution Method
  • Measurement Range:
    • C.O. 0.1 to 20 Umin
    • TB 23 to 43°C
    • TI Oto 27 °C
  • Resolution:
    • C.O. 0.1 Umin
    • TB,TI 0.1°C
  • Accuracy:
    • C.O. ±5% or ±0.1 Umin, whichever is greater, as measured using electronically generated flow curves.
    • TB, Tl ±0.1 (without sensor)
  • Alarm Range:
    • TB 23 to 43°C
  • Repeatability:
    • C.O. ±2% or ±0.1 Umin, whichever is greater, as measured using electronically generated flow curves.

ANESTHETIC AGENTS

  • Method:
    • Infrared absorption
  • Gas Sorts:
    • Halothane, lsoflurane, Enflurane, Sevoflurane, Desflurane, CO2, N2O, 02 (optional Automatic Agent ID)
  • Measurement Range:
    • Halothane, lsoflurane: 0 ~ 8.5% Enflurane, Sevoflurane: 0 ~ 10% Desflurane: 0 ~ 20%
    • CO2: 0 ~ 10%
    • N2O: 0 ~ 100%
    • 02: 0 ~ 100%
  • Bias:
    • Halothane, lsoflurane, Enflurane, Sevoflu rane, Desflurane: ±(0.15 Vol%+ 15% rel.)
    • CO2: ±(0.5 Vol%+ 12% rel.)
    • N2O: ± (2 Vol%+ 8% rel.)
    • 02: ±3 Vol%

OTHER STANDARD FEATURES

  • OxyCRG
  • Drug Dose Calculation
  • Cascading ECG
  • On screen NIPB trends (up to 250 readings)
  • User Set Defaults
  • Arrhythmia Detection
  • ST Segment

Additional information

Brand

Axia