Axia V1200T Touch Screen Patient Monitor

  • Axia V1200T Touch Screen Patient Monitor Multiparameter and ECG Monitors

The Axia V1200T monitor is an intuitive touch screen patient monitor. Patient information along with vital sign settings can be quickly modified to meet the needs of a patient’s changing condition. Its upgradeable design fits-in and moves amongst many patient care areas. Offers ECG with arrhythmia detection, standard measurements of non-invasive blood pressure, motion tolerant SpO2, temperature, respiration rate, and capnography.

The Axia V1200T monitor offers several connective solutions to network multiple monitors and/or manage patient data on an electronic medical records platform or a based hospital information system.

Description

Axia V1200T Touch Screen Patient Monitor Features

  • High resolution 12.1 inch touch-screen display
  • Capnography with EtCO2 monitoring (optional)
  • Auto setting of alarm limits
  • Color-coded alarms
  • Graphical and tabular trends (72 hours)
  • Patient data entry
  • OxiCRG, drug dose calculation
  • Trace: 8 wave forms
  • Trend Time: 1 – 72 Hours
  • Networking capability (wireless and non-wireless)
  • Color of the waveforms can be changed
  • Battery backup (removable batteries)
  • Weight: 8.45 lbs.
  • Applications: Neonatal, pediatric and adult patients

Axia V1200T Touch Screen Patient Monitor SPECIFICATIONS

GENERAL

  • Display: 12.1-inch color touch screen
  • Trace: 8 waveforms
  • Indicator: Alarm indicator Power indicator QRS beep and alarm sound
  • Trend time: 1 – 72 hour
    • Recorder: Built-in, thermal array, 3 channels
    • Record width: 48mm
    • Recorder paper: 50mm
    • Record speed: 25mm/s, 50mm/s

NETWORKING

  • Industry-standard 802.11b/g wireless network

POWER

  • Source:
    • External AC power or internal battery
  • AC Power:
    • 100 ~ 240VAC, 50/60Hz, 150VA
  • Battery:
    • Built-in & rechargeable lithium-ion
  • Operating Time:
    • 3+ hours

ENVIRONMENTAL SPECIFICATIONS

  • Temperature:
    • Operating: 5 ~ 40 °C
    • Storage: -20 ~ 65 °C
  • Humidity range:
    • Operating: ≤80 %
    • Storage: ≤80 %

ECG

  • Input:
    • 5-lead ECG cable and standard AAMI line for connection
  • Lead Choice:
    • I, II, III, aVR, aVF, aVL, V, V1-V6, TEST
  • Gain Choice:
    • x0.5, x1, x2, x4
  • Frequency Characteristic:
    • 0.05 ~ 35 HZ (+3dB)
  • ECG Waveforms:
    • 7 channels
  • Penetration Voltage:
    • 4000VAC 50/60Hz
  • Sweep Speed:
    • 12.5, 25, 50 and 100 mm/sec (left to right or right to left)
  • HR Display Range:
    • 30 ~ 300bpm
  • Accuracy:
    • ±1bpm or ±1%, whichever is greater
  • Alarm Limit Range Setting:
    • Upper limit 100 ~ 200bpm
    • Lower limit 30 ~ 100bpm

RESP

  • Measure Method:
    • RA-LL impedance
  • Range:
    • 0 ~ 120 rpm
  • Accuracy:
    • ±3 rpm
  • Alarm Limit Setting:
    • Upper limit 6 ~ 120 rpm
    • Lower limit 3 ~ 120 rpm
  • Sweep Speed:
    • 12.5, 25, 50 and 100 mm/sec (left to right or right to left)

SPO2

  • ASpO2:
    • Anti-motion SpO2
  • SpO2% Range:
    • 0-100%
  • SpO2 Accuracy:
    • ±2% (70 ~ 100%, non-motion)
    • ±3% (70 ~ 100%, motion)
  • Pulse Rate Range:

    • 30-250 bpm
  • Pulse Rate Accuracy:
    • ±2 bpm (non-motion)
    • ±3 bpm (motion)
  • Alarm Limit Setting:
    • Upper limit 70 ~ 100%
    • Lower limit 70 ~ 100%
  • SpO2 Probe:
    • Red light LED wavelength 660nm±5nm
    • Infrared light LED wavelength 940nm±10nm

NIBP

  • Measuring Technology:
    • Automatic oscillating measurement
  • Cuff Inflating:
    • <30s (0 ~ 300 mmHg, standard adult cuff)
  • Measuring Period:
    • AVE<40s
  • Mode:
    • Manual
    • Auto
  • Measuring Interval in AUTO Mode:
    • 2 min ~ 4 hrs
  • Pulse Rate Range:
    • 30 ~ 250 (bpm)
    • Adult/Pediatric Mode:
      • SYS: 40 ~ 250 (mmHg)
      • DIA :15 ~ 200 (mmHg)
    • Neonatal Mode:
      • SYS: 40 ~ 135 (mmHg)
      • DIA : 15 ~ 100 (mmHg)
  • Maximum Mean error:
    • ±5mmHg
  • Maximum Standard deviation:
    • 8mmHg
  • Resolution:
    • 1mmHg
  • Overpressure Protection:
    • Adult Mode: 300 (mmHg)
    • Neonatal Mode: 160 (mmHg)
  • Alarm Limit Setting:
    • SYS: 50 ~ 240 mmHg
    • DIA: 15 ~ 180 mmHg

TEMPERATURE

  • Range:
    • 25 ~ 50 (°C)
  • Accuracy:
    • ± 0.2°C (25.0 ~ 34.9°C)
    • ± 0.1°C (35.0 ~ 39.9°C)
    • ± 0.2°C (40.0 ~ 44.9°C)
    • ± 0.3°C (45.0 ~ 50.0°C)
  • Display Resolution:
    • 0.1°C
  • Alarm Limit Setting:
    • Upper limit 0 ~ 50°C
    • Lower limit 0 ~ 50°C
  • Channel:
    • 2 Channels

IBP

  • Measurement Range:
    • -50 ~ 300mmHg
  • Channel:
    • 2 channels
  • Pressure Transducer:
    • sensitivity, 5μV/V/mmHg
  • Impedance Range:
    • 300 ~ 3000Ω
  • Transducer Sites:
    • ART, PA,CVP, RAP, LAP, ICP
  • Unit:
    • mmHg/kPa selectable
  • Resolution:
    • 1mmHg
  • Accurancy:
    • ±1mmHg or ±2%, whichever is greater
  • AlarmRange:
    • -10 ~ 300mmHg

ETCO2

  • CO2 Measurement Range:
    • 0 ~ 99mmHg
  • Accuracy:
    • ±2mmHg (0 ~ 38mmHg)
    • 39-99mmHg ±5% of reading +0.08% for every 1mmHg (above 38mmHg)
  • Sampling Rate:
    • 50 ml/min
  • Initialization Time:
    • 30 seconds (typical)
    • Reaches ±5% steady-state accuracy within 3 minutes.
  • Respiration Rate:
    • 0 ~ 150 breaths
  • Mode:
    • Adult
    • Neonate

C.O. (CARDIAC OUTPUT)

  • Measurement Method:
    • Thermodilution Method
  • Measurement Range:
    • C.O. 0.1 to 20 L/min
    • TB 23 to 43℃
    • TI 0 to 27℃
  • Resolution:
    • C.O. 0.1 L/min TB, TI 0.1℃
  • Accuracy:
    • C.O. ±5% or ±0.1 L/min, whichever is greater, as measured using electronically generated flow curves.
    • TB, TI ±0.1(without sensor)
  • Alarm Range:
    • TB 23 to 43℃
  • Repeatability:
    • C.O. ±2% or ±0.1 L/min, whichever is greater, as measured using electronically generated flow curves.

Additional information

Brand

Axia